MY HOME: Project and installation guide - page 608

Màtix catalogue
Catalogue
MyHOME
Item
RELAY ACTUATOR MODULE
3479
actuator module with multiple configuration and
relay output - C-NO-NC contacts, 24 V 0.4 A cos
ϕ
0,4
- to be used for the repeating of various types of alarm
on the basis of its configuration. It can be activated by:
burglar alarms, flat battery signals, closing valve for
technical alarms - basic module
F481
as above - 2 DIN
TECHNICAL ALARM INTERFACE
3481
interface module to receive alarm signals from
AM5731/12 and AM5732/2 gas detector technical
alarm sensors – availability of 5 – 12 Vac/dc input
optoisolated - basic module
F483
as above - 2 DIN
myhome - BUS SCS
Burglar alarm - Technical alarms
NATURAL GAS DETECTORS
AM5731/12
NATURAL GAS detector with visual and sound (85 dB)
alarm notification - internal self-diagnosis - preset
for the control of signal repeaters - powered by a
12 Vac/dc transformer, item AM5734 or item F91/12E
- 2 modules
LPG DETECTORS
AM5732/12
LPG GAS detector with visual and sound (85 dB) alarm
notification - internal self-diagnosis - preset for the
control of signal repeaters - powered by a 12 Vac/dc
transformer, item AM5734 or item F91/12E - 2 modules
FLOOD SENSOR
3482
water detection sensor - to be used together with
the contact interface, item 3480, in technical alarm
mode
3482
Item
EXTERNAL SIREN WITH SYSTEM BATTERY
4072L
external siren including the self-supply battery for the
whole system - sound notification can be set from
0 to 10 minutes by means of the central unit - to be
fitted with a 12 V 12 Ah battery, item 3505/12 - sound
intensity 105 dB (A) at 3 metres - light signaller with
xenon lamp - anti-foam grid - protected against
tearing and opening - to be used with power supply
item E46ADCN
OPTIONAL EXTERNAL SIREN
4072A
self-powered external siren - sound notification can
be set from 0 to 10 minutes by means of the control
unit - to be fitted with a 12 V 7 Ah battery - sound
intensity 105 dB (A) at 3 metres - light signaller with
xenon lamp - anti-foam grid - protected against
tearing and opening - to be used with power supply
item E47ADCN
NOTE:
the external sirens do not include configurators. These may be purchased separately following the
procedure explained in the “Devices and accessories” page.
INTERNAL SIREN
N4070
self-supplied internal siren for installation inside 506E
boxes - to be fitted with a 6 V 0.5 Ah battery, item
3507/6 - sound intensity 90 dB (A) at 3 metres -
protected against tearing and tampering
NOTE:
the external sirens do not include configurators. These may be purchased separately following the
procedure explained in the “Devices and accessories” page.
Tamper
L4630
tamper-proof device for the protection of burglaralarm
devices - reference notches for any type of flush
mounted box
BATTERIES
3507/6
6 V battery for internal siren item N4070
3506
7.2 V battery for central units, item 3485/B
BATTERY FOR EXTERNAL SIREN ITEM 4072L
3505/12
12 V 12 Ah battery
4072L
AM5732/12
3505/12
AM5731/12
1...,598,599,600,601,602,603,604,605,606,607 609,610,611,612,613,614,615,616,617,618,...1184